Volym i liter Volym i literAnvänd draglisten för det volymspann ni önskar se. Klicka sen i t.ex. (material, omrörare, isolering etc.) för att slutligen klicka på FILTRERA, då visas endast de tankar som finns inom de krav ni angett.
Additional information: Adhesive production; Manhole diameter upper bottom: approx. 700 mm; Manhole diameter cylinder: approx. 500 mm Volumetric volume (L): 29.000 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 0,60 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 100 °C Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Volume:…
Additional information: Chemistry; Manhole cylinder diameter 500 mm (most of the manhole cover screws are missing); 1 tank has 1 foot pressed into the lower bottom and the other tank has 2 feet pressed into the lower bottom; (this tank also has 1 connection pressed into the upper bottom and the heating coil is pressed in at one point; the…
Additional information: Sterile tank in a dairy; Double jacket with trickle ring - only suitable for unpressurized tempering; dents in the double jacket in the area of the support timbers; maximum temperature for sterilization in the inner tank 145° C; specified total height according to drawing; 1 former connection in the upper bottom was welded shut by the previous operator…
Additional information: chemistry Volumetric volume (L): 49.338 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Max Overpressure: 6 Bar Max onderdruk: 1 Bar Max. working temperature: 200 °C Type HE on the bottom: half pipe…
Additional information: Brewery; 3 reinforcement rings Fe with 2 feet each (Attention: tank diameter lower than tank feet; note when setting up); 1 manhole in the front floor Volumetric volume (L): 53.000 L Pressure in tank: ATM - atmosferic Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Documents included: no Technical drawing…
Additional information: manhole in the cylinder diameter 600 mm; Complete manufacturer documentation available; A ladder also available upon request; tank has fixtures for field installation of insulation (this fixture is slightly dented); some residues of previous content Volumetric volume (L): 70.000 L Pressure in tank: ATM - atmosferic Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank:…
Additional information: Brewery; 6 reinforcement rings Fe with 2 feet each (Attention: tank diameter lower than tank feet; note when setting up); manhole in the front floor Volumetric volume (L): 72.500 L Pressure in tank: ATM - atmosferic Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: no Documents included: no Technical drawing included:…
item available on order Article type: brand new storage tank Additional information: THE TANKS ARE NOT COMPLETELY READY - PROJECT CANCELLATION - FOR THE INDICATED PRICE THEY CAN BE FINISHED IN SHORT TERM --> 5 TANKS ARE COMPLETELY READY. The conical head side is AISI 316L the rest is AISI 304L. Agitator is not included. Several heating/cooling zones can be…
Additional information: chemistry; Partially small dents in heating coils, slight seizure with shallow depth at the bottom of the jacket Volumetric volume (L): 100.000 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Volume: 230 L…
Additional information: heating oil; Manhole diameter: approx. 600mm; including optical leak detector, tank fitting for heating oil, limit indicator & ladder with stand; Volumetric volume (L): 100.000 L Pressure in tank: ATM - atmosferic Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: no Documents included: no Technical drawing included: no Registration plate on…