Volym i liter Volym i literAnvänd draglisten för det volymspann ni önskar se. Klicka sen i t.ex. (material, omrörare, isolering etc.) för att slutligen klicka på FILTRERA, då visas endast de tankar som finns inom de krav ni angett.
Additional information: rennet-production; Feet originally stood on load cells, these are no longer available (see pictures); according to the type plate, the heating coil is designed for an operating pressure of 3 bar at a temperature of - 5 ° C (see photos on the type plate); diameter manhole 430 mm; suspension of manhole cover incomplete Volumetric volume (L): 3.500…
Additional information: Pharmaceutical Chemistry; 3 support brackets made of Fe; half-coil around the lower cylinder area; 1 heating connection probably slightly bent; bump at the insulation jacket; manhole cover plated Volumetric volume (L): 3.532 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 100 °C Configuration: insulated with heat-exchanger…
Additional information: Pharmacy; Double jacket with electric plug-in heater: 9 kW (incomplete; functionality not guaranteed); presumably the lower cylinder area of the tank can also be heated; manhole approx. 310 x 420 mm; Internal fittings (e.g. welded brackets) inside the tank; some residues of previous content Volumetric volume (L): 3.533 L Pressure in tank: ATM - atmosferic Max. temperature (°C):…
Additional information: Pharmaceutical chemistry; Sight glasses in the manhole covers are missing; support ring, Fe; Flanges partly made of Fe Volumetric volume (L): 3.586 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 200 °C Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total…
Additional information: Pharmaceutical chemistry; Further technical documents available; Sight glass in the manhole cover is missing; support ring, Fe; Flanges partly made of Fe Volumetric volume (L): 3.586 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 200 °C Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no…
Additional information: Chemistry Volumetric volume (L): 3.640 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 0,49 Bar Min. pressure (Bar): 1 Bar Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total discharge: yes Volume: 132 L Max Overpressure: 10 Bar Max. working temperature: 200 °C Type HE on the bottom: half pipe welded onto…
Additional information: Pharmaceutical chemistry; Support ring, Fe; manhole cover incomplete; one tank has most of its heater connections cut off and included loose; 1 tank is approx. 100 mm lower in overall height due to different motor/gear units Volumetric volume (L): 3.690 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max.…
Additional information: Pharmaceutical chemistry; Manhole cover incomplete (among other things, the sight glass is missing, see photos); Support ring made of Fe Volumetric volume (L): 3.690 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 200 °C Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank:…
Article type: brand new pressure tank - type CCT-HIL Volumetric volume (L): 3.850 L Ra inner weld: 0,80 Finish stainless steel: 2B Pressure in tank: pressure Max. pressure (Bar): 3,30 Bar Max. temperature (°C): 50 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 304L (V2A) Model: vertical Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile…
Additional information: Pharmaceutical chemistry; Support ring, Fe; Manhole cover incomplete (see photos); bump at the insulation jacket; manhole cover plated Volumetric volume (L): 3.860 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3,20 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 200 °C Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total discharge:…
Additional information: Full set of pharma-compliant technical documentation included in delivery; tank was manufactured for a global pharmaceutical company but was never put into operation; hand hole with sight glass diameter: 150mm; incl. Südmo single-seat valve SVP (outlet) Volumetric volume (L): 4.000 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Max.…
Additional information: Pharmacy; Half-coil around approx. 900 mm of the cylinder height; Smaller dents in the insulation jacket; Metallic discolouration inside Volumetric volume (L): 4.500 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 150 °C Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total…