item available on order Article type: brand new storage tank - type K3-H12W.IL Volumetric volume (L): 3.300 L Max. density P (kg/m³): 1.500 Ra inner weld: 0,80 Finish stainless steel: 2b Pressure in tank: ATM - atmosferic Max. temperature (°C): 130 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 316L (V4A) Model: vertical Configuration: insulated with heat-exchanger…
item available on order Article type: brand new storage tank - type K3-H12W.IL Volumetric volume (L): 1.500 L Max. density P (kg/m³): 1.200 Ra inner weld: 0,80 Finish stainless steel: 2b Pressure in tank: ATM - atmosferic Max. temperature (°C): 130 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 316L (V4A) Model: vertical Configuration: insulated with heat-exchanger…
item available on order Article type: brand new production tank - type CHC-HILA Additional information: Delivered with food certificate; article price without control panel; see options; (The article can also be purchased without options) Volumetric volume (L): 1.000 L Max. density P (kg/m³): 1.200 Pressure in tank: ATM - atmosferic Max. temperature (°C): 100 °C Min. temperature (°C): -10 °C…
Additional information: Brewery; Struts between the feet made of mild steel (see photos); some residues of previous content Volumetric volume (L): 15.000 L Pressure in tank: pressure Max. pressure (Bar): 1 Bar Max. temperature (°C): 25 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total…
Additional information: chemical industry Volumetric volume (L): 3.000 L Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Type HE on the bottom: heating/cooling jacket Type HE on the cylinder: heating/cooling jacket Documents included: no Technical drawing included:…
Additional information: Tank was manufactured for a global pharmaceutical company but was never put into operation; hand hole with sight glass diameter: 285mm; incl. Südmo single-seat valve SVP (outlet) Volumetric volume (L): 1.000 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 150 °C Material wet parts: SS AISI…
Additional information: Food industry; Heating coil outside around the lower cylinder area; 3 of the feet are equipped with load cells (no guarantee of functionality); one foot is missing the load cell; some residues of previous content Volumetric volume (L): 5.000 L Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: insulated with…
Volumetric volume (L): 1.150 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 80 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Top type: open Total discharge: yes Volume: 4 L Max Overpressure: 5 Bar Max. working temperature: 80 °C Fixation point(s): plastic Documents…
Additional information: Brewery; Loose lid with hinged segment; some residues of previous content Volumetric volume (L): 2.400 L Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total discharge: yes Type HE on the cylinder: heating/cooling jacket Documents included: no Technical drawing…
Additional information: Pharmaceutical chemistry; 3 support brackets, Aisi 304; double jacket for heating/cooling around the lower cylinder area and the lower bottom (double jacket was added later and is not shown in the vessel drawing); slight differences in the design of the two vessels, e.g. differences in the manhole covers and the outlets (1 x outlet diameter approx. 53 mm,…
Additional information: Double jacket must be operated without pressure; 2 electric heaters (6 kW) for heating up the heating medium in the double jacket; Attention: The tank is delivered without heating medium (glycerine or thermal oil), which must be filled in on site before commissioning; control cabinet for the electric heaters available (temperature of the double jacket can be regulated…
Additional information: Cosmetics; Total height including the control cabinet on a stand (see photos from the previous operator); Metallic discolouration inside Volumetric volume (L): 1.000 L Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total discharge: yes Type HE on the…
Additional information: Double jacket must be operated without pressure; 2 electric heaters (6 kW) for heating up the heating medium in the double jacket; Attention: The tank is delivered without heating medium (glycerine or thermal oil), which must be filled in on site before commissioning; control cabinet for the electric heaters available (temperature of the double jacket can be regulated…
Article type: second-hand fermentation tank Additional information: The tanks have never been used; we can’t give any guarantees about the heating/cooling jacket Volumetric volume (L): 1.000 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 20 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation:…
Article type: brand new storage tank - type K-HL Volumetric volume (L): 2.500 L Max. density P (kg/m³): 1.200 Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Top type: conical 15 ° Shape of tank: cylindrical Bottom type: conical 15…
item available on order Article type: brand new pressure tank Volumetric volume (L): 1.300 L Pressure in tank: pressure Max. pressure (Bar): 2 Bar Min. pressure (Bar): -0,15 Bar Max. temperature (°C): 130 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank:…
Additional information: Pharmaceutical chemistry; 2 support brackets made of Aisi 304 (contact surface the other way around; see photos); flanges partly made of Fe; further techn. documents available; In some cases, connections are flanged in the top bottom or at the outlet; using these connections would increase the overall height accordingly; some residues of previous content Volumetric volume (L): 1.300…
Additional information: Outlet DN 60 DIN 11851; reinforcement ribs inside under the upper bottom (removable); 2 fork pockets on the outside of the lower bottom Volumetric volume (L): 530 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 95 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no…
Additional information: Tank was manufactured for a global pharmaceutical company but was never put into operation; hand hole with sight glass diameter: 285mm; incl. Südmo single-seat valve SVP (outlet) Volumetric volume (L): 1.000 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 150 °C Material wet parts: SS AISI…
Additional information: Pharmacy; Mobile frame, Aisi 304; Lid clamping ring is missing Volumetric volume (L): 120 L Pressure in tank: pressure Max. pressure (Bar): 1,50 Bar Max. temperature (°C): 130 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Volume: 16 L Max…
Additional information: chemistry; handhole cover is missing Volumetric volume (L): 1.000 L Pressure in tank: pressure Max. pressure (Bar): 0,50 Bar Max. temperature (°C): 80 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single jacketed with heat-exchanger Heat exchanger: yes Insulation: no Mobile tank: no Total discharge: yes Volume: 26 L Max Overpressure: 1 Bar Max. working…
item available on order Article type: brand new storage tank - type K3-H12W.L Volumetric volume (L): 2.000 L Max. density P (kg/m³): 1.200 Ra inner weld: 0,80 Finish stainless steel: 2b Pressure in tank: ATM - atmosferic Max. temperature (°C): 100 °C Min. temperature (°C): -10 °C Material wet parts: SS AISI 316L (V4A) Model: vertical Configuration: single jacketed with…
Additional information: Dairy; Double jacket probably with trickle ring - only suitable for pressureless tempering; the welding of the double jacket in the upper area has come loose slightly in places; outlet diameter 65 mm (tapers towards the tank to approx. 50 mm); small dents inside the tank; heating connections cut off; pipe end cut flush Volumetric volume (L): 5.530…
Additional information: Pharmacy; The previous operator had the vessels hanging in a ring with load cells that was embedded in the ground (1 ring of each is included in the delivery; see photos); Outer diameter in the ring approx. 1,540 mm; insulating jacket made of material 1.0425 Volumetric volume (L): 885 L Pressure in tank: pressure and vacuum Max. pressure…