Additional information: 1 dip tube inside the tank Volumetric volume (L): 10.000 L Pressure in tank: ATM - atmosferic Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: insulated Heat exchanger: no Insulation: yes Mobile tank: no Total discharge: yes Documents included: no Technical drawing included: no Registration plate on the tank: yes Flange for agitator: no Position of…
Additional information: Pharmacy; Feet with load cells (see photos) Volumetric volume (L): 198 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 6 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 150 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: insulated with heat-exchanger Heat exchanger: yes Insulation: yes Mobile tank: no Total discharge: yes Volume:…
Additional information: Pharmacy Volumetric volume (L): 1.200 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 143 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single-skin Heat exchanger: no Insulation: no Mobile tank: no Total discharge: yes Documents included: no Technical drawing included: no Registration plate…
Additional information: Pharmacy Volumetric volume (L): 800 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 143 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single-skin Heat exchanger: no Insulation: no Mobile tank: no Total discharge: yes Documents included: no Technical drawing included: no Registration plate…
Additional information: Pharmacy; Clamp screws on the upper bottom are partially missing; some residues of previous content Volumetric volume (L): 1.100 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3 Bar Min. pressure (Bar): 1 Bar Max. temperature (°C): 143 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: single-skin Heat exchanger: no Insulation: no Mobile…
Additional information: frame Fe (galvanized) Volumetric volume (L): 1.023 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 80 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single-skin Heat exchanger: no Insulation: no Mobile tank: no Total discharge: yes Fixation point(s): galvanised steel Documents included: no Technical drawing included: no Registration plate on the tank: yes…
Additional information: Double jacket must be operated without pressure; 2 electric heaters (6 kW) for heating up the heating medium in the double jacket; Attention: The tank is delivered without heating medium (glycerine or thermal oil), which must be filled in on site before commissioning; control cabinet for the electric heaters available (temperature of the double jacket can be regulated…
Additional information: Pharmacy; Various technical documents available; the previous operator had the vessels hanging in a ring with load cells that was embedded in the ground (1 ring of each is included in the delivery; see photos) Volumetric volume (L): 1.350 L Pressure in tank: pressure and vacuum Max. pressure (Bar): 3 Bar Min. pressure (Bar): 1 Bar Max. temperature…
Additional information: Dairy; Diameter manhole approx. 420 mm; Insulation around the cylinder (small dents in the insulation jacket) Volumetric volume (L): 1.000 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 90 °C Material wet parts: SS AISI 316 (V4A) Model: vertical Configuration: insulated Heat exchanger: no Insulation: yes Mobile tank: no Total discharge: yes Documents included: no Technical…
Volumetric volume (L): 1.150 L Pressure in tank: ATM - atmosferic Max. temperature (°C): 80 °C Material wet parts: SS AISI 304 (V2A) Model: vertical Configuration: single-skin Heat exchanger: no Insulation: no Mobile tank: no Total discharge: yes Fixation point(s): plastic Documents included: no Technical drawing included: no Registration plate on the tank: yes Flange for agitator: no Outlet of…
Additional information: Double jacket must be operated without pressure; 2 electric heaters (6 kW) for heating up the heating medium in the double jacket; Attention: The tank is delivered without heating medium (glycerine or thermal oil), which must be filled in on site before commissioning; control cabinet for the electric heaters available (temperature of the double jacket can be regulated…
Additional information: Double jacket must be operated without pressure; 2 electric heaters (6 kW) for heating up the heating medium in the double jacket; Attention: The tank is delivered without heating medium (glycerine or thermal oil), which must be filled in on site before commissioning; control cabinet for the electric heaters available (temperature of the double jacket can be regulated…